kWh to kW and Watts Calculator
This kWh to kW and watts calculator converts energy used over a period into average power, and works the other way as a power-to-kWh calculator. It is built for the job business energy users actually do with it: reading half-hourly meter data, finding a site’s maximum demand and working out what a load costs to run.
Average demand over 0.5 hours (30 minutes)
Cost excludes standing charges, capacity charges, Climate Change Levy and VAT.
Check your unit rate with PESkW and kWh are not the same thing
A kilowatt (kW) is power, the rate at which electricity is used at a given moment. A kilowatt hour (kWh) is energy, the amount used over time. A 1 kW heater running for one hour uses 1 kWh. Run it for eight hours and it uses 8 kWh, but it is still a 1 kW heater. Your meter counts kWh, and your bill charges a unit rate for each one.
How the kWh to kW and watts calculator works
If the time is in minutes, divide it by 60 first: 45 minutes is 0.75 hours. The result is an average. A load that cycles on and off, or peaks briefly, will have moments above the average figure.
Worked example: one half-hourly reading
Half-hourly meters record the kWh used in each 30-minute period, 48 readings a day. Because each period is half an hour, the kWh in a half hour × 2 gives the average kW demand in that period. A reading of 50 kWh between 10:00 and 10:30 means the site drew an average of 50 ÷ 0.5 = 100 kW. That is the calculator’s default.
Worked example: maximum demand
A food manufacturer’s highest half-hourly reading in the last 12 months was 87 kWh. Its maximum demand is 87 × 2 = 174 kW. At a power factor of 0.95 that is 174 ÷ 0.95 = 183.2 kVA. Against an agreed supply capacity of 200 kVA, the site has about 16.8 kVA of headroom, so a new 22 kW machine running at the peak would push it over. The kW to kVA calculator does that step for any power factor.
Worked example: kW to kWh
A 3 kW fan heater running for 8 hours uses 3 × 8 = 24 kWh, which costs £6.24 at 26p/kWh. Run it on 260 working days a year and that is 6,240 kWh, or £1,622.40. In minutes mode, a 22 kW EV charger running for 45 minutes delivers 22 × 0.75 = 16.5 kWh, about £4.29 at the same rate. For a full breakdown of what equipment costs to run, try the appliance running cost calculator.
kW to kWh reference table
Energy used by a constant load, with the yearly cost at a typical business rate of 26p/kWh before standing charges, levies and VAT.
| Average demand | kWh per half hour | kWh per day | kWh per year | Cost a year at 26p |
|---|---|---|---|---|
| 1 kW | 0.5 | 24 | 8,760 | £2,278 |
| 5 kW | 2.5 | 120 | 43,800 | £11,388 |
| 10 kW | 5 | 240 | 87,600 | £22,776 |
| 25 kW | 12.5 | 600 | 219,000 | £56,940 |
| 50 kW | 25 | 1,200 | 438,000 | £113,880 |
| 100 kW | 50 | 2,400 | 876,000 | £227,760 |
| 250 kW | 125 | 6,000 | 2,190,000 | £569,400 |
| 500 kW | 250 | 12,000 | 4,380,000 | £1,138,800 |
| 1,000 kW | 500 | 24,000 | 8,760,000 | £2,277,600 |
Read it backwards to go from kWh to kW: a site using 438,000 kWh a year has an average demand of 50 kW, though its peak will be well above that.
Why your bill charges for both
A business electricity bill charges for energy and for capacity separately, because they cost the system different things. Energy is the kWh you use, charged at a unit rate in p/kWh, often split into day, night or time-of-use bands. Capacity is the size of the connection the network keeps ready for you. On a half-hourly metered site it is the agreed supply capacity, charged in pence per kVA per day whether you use it or not.
Maximum demand links the two. The highest half-hourly kW reading, converted to kVA with the power factor, shows whether you are close to your agreed capacity. Exceed it and excess capacity charges follow. Sit far below it and you may be paying for capacity you do not need, which can sometimes be reduced. Load factor matters too: a site whose average kW is close to its peak gets more kWh out of every kVA it pays for.
The unit rate is the part most open to negotiation. If your half-hourly data shows a high, steady load, that profile can win a better price at tender. PES can review your data and tender your contract across the market, and the energy cost calculator shows what a change in unit rate is worth.
Frequently asked questions
How do you convert kWh to watts?
Multiply kWh by 1,000, then divide by the time in hours. For example, 1 kWh used over half an hour is an average of 1 × 1,000 ÷ 0.5 = 2,000 W.
How do you convert kWh to kW?
Divide the kWh by the time in hours. 120 kWh used over 4 hours is an average of 120 ÷ 4 = 30 kW.
How many kW is 1 kWh?
It depends on the time. 1 kWh used in an hour is an average of 1 kW, in 30 minutes it is 2 kW and in 15 minutes it is 4 kW. kWh measures energy and kW measures power, so you always need the time to convert between them.
How many kWh does a 1 kW appliance use?
A 1 kW appliance uses 1 kWh for every hour it runs, or 24 kWh if it runs all day. At a typical business rate of 26p/kWh that is 26p an hour or £6.24 a day.
What is the difference between kW and kWh?
kW is power, the rate of using electricity at a moment. kWh is energy, the total used over time. A 3 kW heater running for 8 hours uses 24 kWh.
How do I work out kW demand from half-hourly data?
Multiply the kWh in a half-hour period by 2. A reading of 50 kWh in one half hour means an average demand of 100 kW in that period.
What is maximum demand?
Maximum demand is the highest average demand a site draws in any half hour, usually over the last 12 months. If the highest half-hourly reading is 87 kWh, the maximum demand is 174 kW, or 183.2 kVA at a power factor of 0.95.
Why does my electricity bill charge for kVA as well as kWh?
Unit rates charge for the energy you use in kWh. Capacity charges pay for the size of your connection, set as an agreed supply capacity in kVA and charged per kVA per day whether you use it or not.
How much does 100 kWh of electricity cost a business?
At a typical unit rate of 26p/kWh, 100 kWh costs £26.00. Adding Climate Change Levy at 0.801p/kWh makes it £26.80, and £32.16 with 20% VAT, before standing and capacity charges.
Got half-hourly data and not sure what it says? We can read your demand profile, check your capacity and tender your contract across the market.
Get in touchRelated tools and services
- Business Energy Cost CalculatorBuild a business bill with CCL, VAT and all-in p/kWh
- Appliance Running Cost CalculatorRunning cost of office and site equipment, item by item
- kW to kVA CalculatorApparent and reactive power from kW and power factor
- kVA to kW CalculatorReal power from any kVA rating, with kVAr
- Compare business energyTender your contract across the market