Skip to main content

Appliance Running Cost Calculator for Business Equipment

This appliance running cost calculator shows how much it costs to run the equipment in an office, shop, kitchen or workshop. Add each appliance with its wattage, how many you have and how long they run, and it totals the cost a year, a month and a day, then ranks the items so you can see which ones drive the bill.

Free calculator

Appliance running cost calculator

Appliance 1
Appliance
Watts
W
Quantity
Hours a day
h
Days a week
Appliance 2
Appliance
Watts
W
Quantity
Hours a day
h
Days a week
p/kWh

26p/kWh is a typical business electricity rate. Use the unit rate from your bill, or the all-in rate from our energy cost calculator to include CCL and VAT. Wattages are typical figures; the rating plate on the equipment gives the real one. A year is 52 weeks.

Running cost a year
£1,014.00

3,900 kWh a year at 26p/kWh

Per month£84.50
Per day (average over 365 days)£2.78
Energy used a year3,900 kWh
Where the money goes
  1. 10 × Office PCBiggest cost£811.203,120 kWh, 80%
  2. 1 × Kettle£202.80780 kWh, 20%
Working, biggest cost10 × 150 W × 8 h × 5 days × 52 weeks ÷ 1,000 = 3,120 kWh × 26p = £811.20
Lower your unit rate with PES

How much does it cost to run an appliance?

The running cost depends on three things: how much power the appliance draws, how long it runs and what you pay for each kWh. Power in watts multiplied by hours gives watt hours; dividing by 1,000 turns that into kWh, the unit on your electricity bill.

kWh = watts × quantity × hours a day × days a week × 52 ÷ 1,000
Cost = kWh × unit rate ÷ 100

The calculator uses 52 weeks a year. For equipment that runs around the clock, such as a fridge or a server, enter 24 hours and 7 days.

Worked example: a 10 person office

Ten desktop PCs at 150 W running 8 hours a day, 5 days a week, use 10 × 150 × 8 × 5 × 52 ÷ 1,000 = 3,120 kWh a year. At 26p/kWh that is £811.20. A 3,000 W kettle used for an hour a day adds 780 kWh and £202.80. Together they cost £1,014 a year, or £84.50 a month, and the PCs make up 80% of it.

Worked example: portable heaters

A single 3 kW fan heater running 8 hours a day, 5 days a week through a 26 week heating season uses 3,120 kWh and costs £811.20. That is as much as all ten PCs use in a whole year. Fan heaters are one of the most expensive ways to heat a space; a heat pump delivers about three times as much heat for each kWh. See our heat pump running cost calculator to compare.

Typical wattages and cost per hour

Typical figures for business equipment at 26p/kWh. The rating plate on each item gives its actual power, and many items, such as fridges and air conditioning, cycle on and off so their average draw is lower than their peak.

ApplianceTypical powerCost per hourCost per 8 hour day
Kettle3,000 W78p£6.24
Office PC150 W3.9p31.2p
Monitor30 W0.78p6.24p
Server500 W13p£1.04
Fridge (average)150 W3.9p31.2p
2 kW fan heater2,000 W52p£4.16
3 kW fan heater3,000 W78p£6.24
Air conditioning unit2,500 W65p£5.20
LED panel36 W0.94p7.49p
Fluorescent fitting70 W1.82p14.56p
Dishwasher1,800 W46.8p£3.74
Commercial oven5,000 W£1.30£10.40
Compressor7,500 W£1.95£15.60
EV charger7,000 W£1.82£14.56

If you only know the current an appliance draws, use our power calculator to turn amps and volts into watts first.

Quick wins for offices

Switch-off policies

An office is empty for 128 of the 168 hours in a week. A PC left on overnight and at weekends might idle at around 50 W; across ten PCs that is 3,328 kWh and £865.28 a year for nothing. Shutting down at night, sleep settings that kick in after 15 minutes and timers on printers, water boilers and vending machines cost almost nothing to set up.

LED lighting

Swapping a 70 W fluorescent fitting for a 36 W LED panel saves 34 W per fitting. In an office with 40 fittings lit 10 hours a day, 5 days a week, that saves 3,536 kWh and £919.36 a year at 26p/kWh, and LED panels need far less maintenance. Add presence detection in meeting rooms and toilets and the saving grows.

Heating and cooling

Heating and cooling usually beat everything else on the list. Set air conditioning to no lower than 24°C, stop it fighting the heating, and replace portable heaters with a proper system.

Why the unit rate matters as much as the kit

Every figure above scales with the unit rate. The same office paying 31p/kWh instead of 26p/kWh spends £1,209 a year instead of £1,014 on the same equipment. Your bill also adds standing charges, the Climate Change Levy and VAT; our energy cost calculator builds the full bill and gives your all-in rate per kWh to use here. To bring the rate itself down, compare business energy with PES.

Frequently asked questions

How do I work out how much an appliance costs to run?

Multiply the power in watts by the hours it runs, divide by 1,000 to get kWh, then multiply by your unit rate. A 2,000 W heater running for 3 hours uses 6 kWh, which costs £1.56 at 26p/kWh.

How much does it cost to run a kettle?

A 3,000 W kettle costs 78p an hour at 26p/kWh. A typical 3 minute boil uses 0.15 kWh, which is about 3.9p.

How much does it cost to run an office computer?

A desktop PC drawing 150 W uses 1.2 kWh in an 8 hour day, which costs 31.2p at 26p/kWh. Over 5 days a week for 52 weeks that is £81.12 a year, before the monitor.

How much does a fan heater cost to run?

At 26p/kWh a 2 kW fan heater costs 52p an hour and a 3 kW fan heater costs 78p an hour. Running a 3 kW heater for an 8 hour day costs £6.24.

How much does air conditioning cost to run per hour?

A 2,500 W air conditioning unit costs 65p an hour at full power at 26p/kWh, or £5.20 for an 8 hour day. Modern inverter units often run below full power once the room is at temperature, so the real cost is usually lower.

How much does it cost to run a fridge all year?

A fridge averaging 150 W uses 3.6 kWh a day, about 93.6p at 26p/kWh. Over a year that is 1,314 kWh, or £341.64.

How much does a server cost to run?

A server drawing 500 W around the clock uses 4,380 kWh a year, which costs £1,138.80 at 26p/kWh. The air conditioning that keeps the room cool adds to that.

How much does switching to LED lighting save?

Replacing a 70 W fluorescent fitting with a 36 W LED panel saves 34 W. At 10 hours a day, 5 days a week, that is 88.4 kWh a year, or £22.98 per fitting at 26p/kWh.

Every appliance on site runs on the same unit rate. We can review your electricity contract and tender it across the market to bring that rate down.

Get in touch