Skip to main content

Volts to Watts Calculator

This volts to watts calculator turns a voltage and a current into power in watts and kilowatts, for DC circuits, single-phase AC and three-phase AC. Enter the supply voltage, the current the load draws and, on AC, the power factor, and it shows the watts with the working. The one thing it cannot do is turn volts alone into watts, and the reason is worth knowing.

Free calculator

Convert volts to watts

Supply type

Use a power factor of 1 for heaters, kettles and EV chargers. Use 0.8 to 0.95 for motors, pumps and compressors. Not sure? 0.9 is a sensible figure for a mixed business site.

Power
2,300W

Single-phase at 230 V and 10 A

In kilowatts
2.30 kW
Apparent power
2.30 kVA
Energy in one hour
2.30 kWh
Cost an hour at 26p/kWh (typical)
£0.60
WorkingP = 230 V × 10 A × 1 = 2,300 W

The running cost uses a typical business unit rate of 26p/kWh, excluding standing charges, levies and VAT.

Check your unit rate with PES

Why volts alone cannot give you watts

Voltage is the electrical pressure a supply provides. Power is how fast energy is used, and that depends on how much current the load pulls at that pressure. Every socket in a UK building sits at about 230 V, yet a phone charger plugged into one uses around 5 W and a kettle uses 3,000 W. The voltage is the same; the current is what changes. So to convert volts to watts you always need the amps as well, and on AC the power factor too.

If you know the resistance instead of the current, the power calculator works from any two of volts, amps, ohms and watts.

Volts to watts formulas

DC

Watts = volts × amps

DC has no power factor. A 12 V device drawing 5 A uses 12 × 5 = 60 W. A 48 V battery system delivering 100 A supplies 48 × 100 = 4,800 W, or 4.8 kW.

Single-phase AC

Watts = volts × amps × power factor

A 230 V heater drawing 10 A, with a power factor of 1, uses 230 × 10 × 1 = 2,300 W. That is the calculator’s default. A motor drawing the same 10 A at a power factor of 0.85 delivers only 1,955 W of real power, because part of its current is reactive.

Three-phase AC (line to line voltage)

Watts = 1.732 × volts × amps × power factor

A balanced three-phase load on a 400 V supply drawing 32 A per phase at a power factor of 0.9 uses 1.732 × 400 × 32 × 0.9 = 19,953 W, or about 20 kW. At a power factor of 1 the same current would carry 22,170 W. For the full three-phase picture, including kVA and current per phase, use the three-phase power calculator.

Volts to watts conversion table

Watts for common currents at standard voltages. The AC columns use UK voltages: 230 V single-phase at a power factor of 1 and 400 V three-phase at a power factor of 0.9.

Current12 V DC24 V DC230 V 1-phase400 V 3-phase, PF 0.9
1 A12 W24 W230 W624 W
5 A60 W120 W1,150 W3,118 W
10 A120 W240 W2,300 W6,235 W
13 A156 W312 W2,990 W8,106 W
16 A192 W384 W3,680 W9,977 W
20 A240 W480 W4,600 W12,471 W
32 A384 W768 W7,360 W19,953 W
40 A480 W960 W9,200 W24,942 W
63 A756 W1,512 W14,490 W39,283 W
100 A1,200 W2,400 W23,000 W62,354 W

Going the other way, from a power rating to the current it draws, is what the kW to amps calculator does.

Why it matters for a business

The current your supply can carry sets the most power you can draw at once. A 100 A single-phase supply tops out at 23 kW. A 100 A three-phase supply, the largest that can use a whole-current meter, gives about 69 kVA. Beyond that a site needs CT metering, and its agreed supply capacity in kVA becomes a line on every bill, with excess capacity charges if you go over it.

Watts also convert straight into cost. Every 1,000 W running for an hour is 1 kWh, so the 20 kW three-phase load above costs about £5.19 an hour at a typical business rate of 26p/kWh. A load that runs 2,000 hours a year at that rate costs about £10,376. If you are adding equipment on that scale, the capacity and the contract both matter, and PES can compare business energy contracts to make sure the unit rate is right.

Frequently asked questions

How do you convert volts to watts?

You cannot convert volts to watts on their own; you also need the current. Multiply volts by amps, and on AC by the power factor too. So 230 V × 10 A × a power factor of 1 is 2,300 W.

How many watts is 230 volts?

It depends on the current. At 230 V, 1 A is 230 W, 10 A is 2,300 W and 13 A, the limit of a UK plug, is 2,990 W.

How many watts is 12 volts?

Again it depends on the current. A 12 V DC device drawing 1 A uses 12 W, and one drawing 5 A uses 60 W.

How many watts is 240 volts at 13 amps?

240 V × 13 A is 3,120 W, or 3.12 kW. At the UK nominal 230 V the same 13 A is 2,990 W.

How many watts is 400 V three-phase at 32 amps?

Multiply 1.732 × 400 × 32 to get 22,170 W, or 22.2 kW, at a power factor of 1. At a power factor of 0.9 it is 19,953 W, or about 20 kW.

How many watts is 100 amps?

On a 230 V single-phase supply, 100 A is 23,000 W, or 23 kW. On a 400 V three-phase supply, 100 A per phase is 69,282 W at a power factor of 1, about 69 kW.

Why does my supply read 240 V when the UK is 230 V?

The UK nominal voltage is 230 V with a tolerance of +10% and −6%, so anything from 216.2 V to 253 V is within limits. Many sites measure about 240 V, which gives 4.3% more watts than the nominal figure for the same current.

Planning new load or a supply upgrade? We can check your capacity, review your supply contract and tender it across the market.

Get in touch