Gas Meter Reading to kWh Calculator
Use the calculator above to convert a gas meter reading to kWh, the unit your supplier bills in. It shows the kWh, the cost and every step of the working. It also works as an m3 to kWh calculator: enter a previous reading of 0 and the volume in cubic metres as the current reading.
500 m³ on a metric meter
Cost covers unit charges only. Standing charges, Climate Change Levy at 0.801p/kWh and VAT are added on your bill.
Ask PES to check your gas billsHow to convert a gas meter reading to kWh
A gas meter measures volume, not energy. To turn a reading into kWh, your supplier takes the units used, converts them to cubic metres if needed, corrects the volume for temperature and pressure, multiplies by the energy content of the gas and converts megajoules to kWh. Every UK supplier uses this method, set out in the Gas (Calculation of Thermal Energy) Regulations.
The 3.6 converts megajoules to kWh, because 1 kWh is 3.6 MJ.
Imperial and metric meters
Metric meters read in cubic metres and usually show M³ on the face. Older imperial meters read in hundreds of cubic feet and usually show ft³ or cubic feet. For an imperial meter, multiply the units by 2.83 first to get cubic metres. Getting this wrong is a common billing error. Some larger meters also show a multiplier, such as × 10, which applies to the units before anything else.
What the calorific value means
The calorific value (CV) is the energy in a cubic metre of gas, in MJ/m³. It varies a little with where the gas came from, so it is measured every day for each region. Your bill shows the average CV for the billing period, usually between 37.5 and 43. A higher CV means more kWh from the same volume.
What the correction factor means
Gas expands when it is warmer and compresses under pressure, so the same volume does not always hold the same amount of gas. The correction factor adjusts the measured volume to standard conditions. Sites using under 732,000 kWh a year use a fixed factor of 1.02264. Larger sites, often with metering at higher pressure, have a factor set for that site, which is why the calculator lets you change it.
Worked examples
Metric meter
The previous reading is 12,000 and the current reading is 12,500, so 500 m³ has been used. With a CV of 39.5 MJ/m³:
At a typical business unit rate of 10p/kWh that is £561.03 in unit charges.
Imperial meter
An imperial meter moves from 4,210 to 4,330, which is 120 hundreds of cubic feet. Multiply by 2.83 to get 339.6 m³. Then 339.6 × 1.02264 × 39.5 ÷ 3.6 = 3,810.5 kWh, or £381.05 at 10p/kWh. Had the readings been treated as metric by mistake, the bill would show only 1,346.5 kWh.
When the meter goes round the clock
If the current reading is lower than the previous one, the dial may have rolled over. A five digit meter that goes from 99,800 to 00,300 has used 200 units to reach 99,999 and zero, plus 300 more, so 500 units in total. The calculator assumes a roll over only when the previous reading was close to the top of the dial. Otherwise it flags the readings, because an estimate that was too high is more likely.
m3 to kWh conversion table
Using the standard correction factor of 1.02264.
| Cubic metres | CV 37.5 | CV 39.5 | CV 41.0 |
|---|---|---|---|
| 1 m³ | 10.7 kWh | 11.2 kWh | 11.6 kWh |
| 10 m³ | 106.5 kWh | 112.2 kWh | 116.5 kWh |
| 100 m³ | 1,065.2 kWh | 1,122.1 kWh | 1,164.7 kWh |
| 250 m³ | 2,663.1 kWh | 2,805.2 kWh | 2,911.7 kWh |
| 500 m³ | 5,326.3 kWh | 5,610.3 kWh | 5,823.4 kWh |
| 1,000 m³ | 10,652.5 kWh | 11,220.6 kWh | 11,646.7 kWh |
| 2,500 m³ | 26,631.3 kWh | 28,051.6 kWh | 29,116.8 kWh |
| 5,000 m³ | 53,262.5 kWh | 56,103.2 kWh | 58,233.7 kWh |
| 10,000 m³ | 106,525.0 kWh | 112,206.3 kWh | 116,467.3 kWh |
Checking a business gas bill
Your bill should show the readings, whether each one was actual (A) or estimated (E), the meter type, the CV, the correction factor and the kWh. Run the same figures through the calculator and the kWh should match to within rounding. If it does not, check these first:
- Estimated readings. A run of estimates can overstate use for months. Send an actual reading and ask for the account to be re-billed.
- Meter type. An imperial meter billed as metric, or the reverse, puts the bill out by a factor of 2.83.
- Calorific value. The CV should be the average for the billing period. On 2,000 m³, a CV of 40.2 instead of 39.5 adds 397.7 kWh.
Once you have the kWh, our therms to kWh converter puts it in the units wholesale gas is traded in, and the energy cost calculator builds up the full annual cost with standing charges, Climate Change Levy and VAT.
Why it matters for a business
Gas billing errors can run for years before anyone notices, and checking the conversion from readings to kWh is the simplest bill validation there is. Accurate kWh figures also matter at renewal, because suppliers price your contract on the annual volume you declare. If your bills look wrong, or your contract is coming up for renewal, talk to PES.
Frequently asked questions
How do I convert a gas meter reading to kWh?
Take the previous reading away from the current one, multiply by 2.83 if the meter is imperial, then multiply by the correction factor of 1.02264 and the calorific value, and divide by 3.6. On a metric meter, 500 m³ at a calorific value of 39.5 MJ/m³ is 5,610.3 kWh.
How many kWh is 1 m³ of gas?
At a calorific value of 39.5 MJ/m³ and the standard correction factor, 1 m³ of gas is 11.22 kWh. Across the usual range of calorific values it runs from 10.65 kWh at 37.5 to 12.21 kWh at 43.
How many kWh is 100 cubic feet of gas?
100 cubic feet is 2.83 m³, which is 31.75 kWh at a calorific value of 39.5 MJ/m³. One unit on an imperial meter is 100 cubic feet.
How do I know if my gas meter is metric or imperial?
A metric meter usually shows M³ or cubic metres on the face. An imperial meter usually shows ft³ or cubic feet and reads in hundreds of cubic feet. If you are unsure, your bill states the meter type.
What is the calorific value on my gas bill?
It is the energy in a cubic metre of gas, in megajoules. It is measured daily and is usually between 37.5 and 43 MJ/m³, and your bill uses the average for the billing period. A CV of 39.5 means each corrected cubic metre holds 10.97 kWh.
What is the 1.02264 correction factor?
It adjusts the volume measured by the meter to standard temperature and pressure. Sites using under 732,000 kWh a year use the fixed figure of 1.02264. Larger sites can have a factor calculated for that site.
What if my current gas reading is lower than my previous one?
Either the dial has gone round the clock, or the previous reading was an estimate that was too high. A five digit meter going from 99,800 to 00,300 has used 500 units. If the previous reading was nowhere near the top of the dial, ask your supplier to re-bill from an actual reading.
How much does 500 m³ of gas cost?
500 m³ at a calorific value of 39.5 MJ/m³ is 5,610.3 kWh. At a typical business unit rate of 10p/kWh that is £561.03, before the standing charge, Climate Change Levy and VAT.
Not sure your gas bills add up? We can check your readings, conversions and charges, then tender your contract across the market.
Get in touchRelated tools and services
- Therms to kWh ConverterTherms, kWh, MWh, MJ and BTU in any direction
- Business Energy Cost CalculatorBuild a business bill with CCL, VAT and all-in p/kWh
- Energy Price Converterp/therm, p/kWh, £/MWh and €/MWh in any direction
- Heat Pump Running Cost CalculatorHeat pump vs gas boiler, with the break-even SCOP
- Compare business energyTender your gas contract across the market
- Talk to PESGet your gas bills checked
- All free calculatorsEvery PES energy and electrical calculator